0412 333 115
0412 333 115
If you’re an electrician, HVAC tech, or even a DIY-savvy homeowner in Australia, you already know that safety is non-negotiable when it comes to electricity.
Whether you’re rewiring a home in Western Australia, testing motors in Tasmania, or maintaining equipment in South Australia, one of the most critical checks you can do is a proper insulation test.
But here’s the catch — how exactly do you test insulation properly? And which tools can you trust to give you reliable, safe results?
That’s where this guide comes in.
We’ve put together a simple, friendly, step-by-step insulation testing guide using Uni-T testers, designed specifically for Australian readers.
Here’s what you’ll learn:
✅ Why insulation testing matters in Australia.
✅ How to test insulation resistance with a Uni-T tester (explained simply).
✅ Aussie buyer’s guide: tips for choosing the right tester for your needs.
✅ Our pick for the best Uni-T tester in 2025.
✅ A real-life customer story from Tasmania.
By the time you’re done reading, you’ll feel confident about testing insulation the right way — and you’ll know where to get the gear you need at a fair price.
So why is insulation testing so important?
The short answer: because bad insulation is dangerous.
⚡ Electric shocks to you or your client.
⚡ Electrical fires due to leakage currents.
⚡ Failed inspections and costly repairs.
Australia’s environment is tough on insulation:
In WA, hot dry air can crack and degrade insulation.
In Tasmania, moisture and condensation creep into everything.
In SA, dust and salty winds can cause tracking and contamination.
Regular insulation testing helps you catch problems early — before someone gets hurt or something burns out.
If you’ve never done it before, testing insulation might sound intimidating — but it’s not as hard as it sounds.
Here’s a quick, no-jargon explanation.
It’s the ability of the material around a conductor (like the plastic sheath on a cable) to stop electricity from leaking out.
We measure it in megaohms (MΩ) — the higher the number, the better the insulation.
1️⃣ Turn Off the Power
You must disconnect and isolate the circuit you’re testing. Never test a live circuit.
2️⃣ Select the Right Voltage
Use the dial to pick your test voltage — usually 500V DC for general circuits, 250V DC for sensitive electronics, or 1000V DC for high-voltage equipment.
3️⃣ Connect the Leads
Attach one lead to the active conductor and the other to earth (or between conductors if you’re testing phase-to-phase).
4️⃣ Press Test
Press and hold the test button. Watch the resistance reading — it should climb and stabilise.
5️⃣ Check the Reading
For most circuits, you’re looking for at least 1 MΩ at 500V, as per Australian standards.
6️⃣ Discharge and Disconnect
Good testers (like Uni-T) automatically discharge the circuit when you let go of the button. Disconnect the leads and you’re done.
You can check out Uni-T’s full range of insulation testers here:
👉 Shop Uni-T Insulation Testers
Not all testers are created equal — and not all are suited for Australian worksites.
Here are a few buyer’s tips based on what we’ve learned from sparkies in WA, Tassie, and SA:
For Aussie jobs, you’ll want at least 500V DC, with 250V and 1000V options for flexibility.
Outdoors in bright WA sun? Or inside a dark Tasmanian basement? Uni-T testers have both analogue needles and digital readouts — great for all conditions.
You’ll want a case that can handle a bit of punishment and keep your leads tidy — essential if you’re moving between jobs in dusty SA or wet Tassie.
Skip the dodgy imports. Order from a local supplier like HVAC Trade Supply so you get fast shipping, genuine gear, and proper support.
After trying a few options, we reckon the Uni-T UT502A is the best choice for most Aussie tradies in 2025.
Here’s why:
✔ Voltage options: 250V, 500V, 1000V — covers everything you need.
✔ Reads up to 2000 MΩ — way above the minimum required.
✔ Compact, rugged, and comes with a carry case and quality leads.
✔ Affordable — heaps of value compared to more expensive brands.
You can grab yours here:
👉 Shop Uni-T Insulation Testers
Sarah runs her own electrical business in Hobart. She often finds herself crawling under old heritage homes with damp wiring.
“My old tester kept sticking and giving me dodgy readings,” Sarah says. “Plus, it didn’t even have a 1000V setting for the industrial jobs.”
After an inspector gave her a warning about her equipment, she ordered the Uni-T UT502A from HVAC Trade Supply.
“It’s brilliant,” Sarah says. “Easy to use, super clear readings, and I can finally show inspectors results that meet standards. Even my apprentice loves using it because it’s so simple.”
If you want to do the job right — and keep yourself and your clients safe — a proper insulation tester is your best mate.
👉 Explore the Full Range of Uni-T Insulation Testers
Fast shipping to Western Australia, Tasmania, South Australia — and everywhere in between.
For general circuits, at least 1 MΩ at 500V DC is the minimum according to Australian standards.
Absolutely — higher-end models even go up to 2500V for heavy-duty testing.
That’s normal — insulation needs a few seconds to stabilise under test voltage.
Yes — HVAC Trade Supply ships all over Australia, including WA, Tassie, and SA.
{"one"=>"Select 2 or 3 items to compare", "other"=>"{{ count }} of 3 items selected"}