{"product_id":"secop-sc15g-medium-back-pressure-compressor-r134a-3-8hp-sc15g","title":"Secop SC15G Medium Back Pressure Compressor R134a 3\/8 HP | SC15G","description":"\u003cdiv style=\"text-align: left; color: #26313d;\"\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.65; margin-bottom: 16px;\"\u003eThe Secop SC15G is a medium back pressure (MBP) compressor designed for R134a refrigeration systems. It provides 3\/8 HP capacity and is suited for commercial refrigeration applications such as refrigerators, prep benches, and display units.\u003c\/p\u003e\n\u003ch2 style=\"color: #14212e; font-size: 20px; border-left: 5px solid #d97706; padding: 2px 0 2px 12px; margin-top: 32px; margin-bottom: 14px; text-transform: uppercase; letter-spacing: 0.02em;\"\u003ePart Identification\u003c\/h2\u003e\n\u003cul style=\"font-size: 15px; line-height: 1.65; margin-bottom: 16px; padding-left: 20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e SC15G\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Secop\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Codes:\u003c\/strong\u003e 104G8520, 104G8530\u003c\/li\u003e\n\u003cli\u003eNo supersession data is listed for this part number.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #14212e; font-size: 20px; border-left: 5px solid #d97706; padding: 2px 0 2px 12px; margin-top: 32px; margin-bottom: 14px; text-transform: uppercase; letter-spacing: 0.02em;\"\u003eWhere This Part Is Used\u003c\/h2\u003e\n\u003cul style=\"font-size: 15px; line-height: 1.65; margin-bottom: 16px; padding-left: 20px;\"\u003e\n\u003cli\u003eCommercial refrigerators\u003c\/li\u003e\n\u003cli\u003ePrep benches\u003c\/li\u003e\n\u003cli\u003eRefrigerated display units\u003c\/li\u003e\n\u003cli\u003eGeneral commercial refrigeration applications requiring R134a and medium back pressure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.65; margin-bottom: 16px;\"\u003eModel coverage can change across production runs — confirm against your unit's data plate before ordering.\u003c\/p\u003e\n\u003ch2 style=\"color: #14212e; font-size: 20px; border-left: 5px solid #d97706; padding: 2px 0 2px 12px; margin-top: 32px; margin-bottom: 14px; text-transform: uppercase; letter-spacing: 0.02em;\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 15px; margin-bottom: 18px; border-top: 2px solid #14212e;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #14212e; padding: 9px 10px; text-align: left; background-color: #eef1f4; border-bottom: 1px solid #d5dbe1; width: 38%;\"\u003eRefrigerant\u003c\/th\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003eR134a\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #14212e; padding: 9px 10px; text-align: left; background-color: #eef1f4; border-bottom: 1px solid #d5dbe1; width: 38%;\"\u003eHorsepower (HP)\u003c\/th\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003e3\/8 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #14212e; padding: 9px 10px; text-align: left; background-color: #eef1f4; border-bottom: 1px solid #d5dbe1; width: 38%;\"\u003eVoltage\u003c\/th\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003e220–240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #14212e; padding: 9px 10px; text-align: left; background-color: #eef1f4; border-bottom: 1px solid #d5dbe1; width: 38%;\"\u003eDisplacement\u003c\/th\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003e15.28 cm³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #14212e; padding: 9px 10px; text-align: left; background-color: #eef1f4; border-bottom: 1px solid #d5dbe1; width: 38%;\"\u003eCooling Output (–20°C)\u003c\/th\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003e290W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #14212e; padding: 9px 10px; text-align: left; background-color: #eef1f4; border-bottom: 1px solid #d5dbe1; width: 38%;\"\u003eCooling Output (+10°C)\u003c\/th\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003e1340W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"color: #14212e; font-size: 20px; border-left: 5px solid #d97706; padding: 2px 0 2px 12px; margin-top: 32px; margin-bottom: 14px; text-transform: uppercase; letter-spacing: 0.02em;\"\u003eCheck Before You Order\u003c\/h2\u003e\n\u003col style=\"font-size: 15px; line-height: 1.65; margin-bottom: 16px; padding-left: 20px;\"\u003e\n\u003cli\u003eVerify the refrigerant type required by your system, ensuring it is R134a.\u003c\/li\u003e\n\u003cli\u003eConfirm the voltage and horsepower match your existing compressor or unit's specification.\u003c\/li\u003e\n\u003cli\u003eCompare the physical dimensions and mounting points against your installation space.\u003c\/li\u003e\n\u003cli\u003eCheck the connection types and sizes for suction and discharge lines.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 style=\"color: #14212e; font-size: 20px; border-left: 5px solid #d97706; padding: 2px 0 2px 12px; margin-top: 32px; margin-bottom: 14px; text-transform: uppercase; letter-spacing: 0.02em;\"\u003eFitting Notes\u003c\/h2\u003e\n\u003cul style=\"font-size: 15px; line-height: 1.65; margin-bottom: 16px; padding-left: 20px;\"\u003e\n\u003cli\u003eInstallation requires a current ARCtick licence for handling refrigerants.\u003c\/li\u003e\n\u003cli\u003eEnsure the system is fully evacuated and correctly charged with the specified refrigerant type and quantity.\u003c\/li\u003e\n\u003cli\u003eProper oil selection and level are critical for compressor longevity; refer to manufacturer guidelines.\u003c\/li\u003e\n\u003cli\u003eConfirm electrical connections and wiring are compliant with local standards and the compressor's voltage rating.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #14212e; font-size: 20px; border-left: 5px solid #d97706; padding: 2px 0 2px 12px; margin-top: 32px; margin-bottom: 14px; text-transform: uppercase; letter-spacing: 0.02em;\"\u003eOrdering \u0026amp; Availability\u003c\/h2\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.65; margin-bottom: 16px;\"\u003eThis Secop SC15G compressor is sold individually and is a genuine OEM component. Current stock levels and estimated lead times are displayed during the checkout process. Order from HVAC Trade Supply.\u003c\/p\u003e\n\u003ch2 style=\"color: #14212e; font-size: 20px; border-left: 5px solid #d97706; padding: 2px 0 2px 12px; margin-top: 32px; margin-bottom: 14px; text-transform: uppercase; letter-spacing: 0.02em;\"\u003eCommonly Ordered With\u003c\/h2\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.65; margin-bottom: 16px;\"\u003eCustomers frequently order filter dryers, capillary tubes, and refrigeration oil when replacing compressors.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Automated FAQ Schema --\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Does the Secop SC15G supersede or is it superseded by other parts?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The Secop SC15G does not have listed supersession data, however, manufacturer codes 104G8520 and 104G8530 are associated with this compressor. Always verify compatibility using the specific part number and specifications.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Which units or series does the SC15G compressor fit?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The SC15G is suitable for commercial refrigeration applications such as refrigerators, prep benches, and display units that require R134a and a medium back pressure compressor. Always confirm compatibility against your unit's data plate and existing compressor specifications.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Does fitting this compressor require a licensed tradesperson?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes, installation of the Secop SC15G compressor involves handling refrigerants and electrical connections. This work must be carried out by an appropriately qualified and ARCtick licensed HVAC\/R technician in Australia.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e","brand":"Secop","offers":[{"title":"Default Title","offer_id":50320969695469,"sku":"SC15G","price":235.07,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/2737\/6621\/files\/158_medium_20back_20compressors.jpg?v=1784784263","url":"https:\/\/www.hvactradesupply.com.au\/products\/secop-sc15g-medium-back-pressure-compressor-r134a-3-8hp-sc15g","provider":"HVAC Trade Supply","version":"1.0","type":"link"}