{"product_id":"secop-sc12cl-compressor-r404a-r507-3-8hp-sc12cl","title":"Secop SC12CL Compressor R404A\/R507 3\/8 HP","description":"\u003cdiv style=\"text-align: left; color: #26313d;\"\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.65; margin-bottom: 16px;\"\u003eThe Secop SC12CL is a 3\/8 HP low back pressure (LBP) compressor for R404A and R507 refrigerant systems. It is designed for low-temperature refrigeration applications requiring stable cooling and dependable performance. This unit operates on 220–240V power supplies.\u003c\/p\u003e\n\u003ch2 style=\"color: #14212e; font-size: 20px; border-left: 5px solid #d97706; padding: 2px 0 2px 12px; margin-top: 32px; margin-bottom: 14px; text-transform: uppercase; letter-spacing: 0.02em;\"\u003ePart Identification\u003c\/h2\u003e\n\u003cul style=\"font-size: 15px; line-height: 1.65; margin-bottom: 16px; padding-left: 20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e SC12CL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Secop\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number (MPN):\u003c\/strong\u003e 104L2623\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Category:\u003c\/strong\u003e Hermetic Compressor\u003c\/li\u003e\n\u003cli\u003eNo supersession data is listed for this part number.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #14212e; font-size: 20px; border-left: 5px solid #d97706; padding: 2px 0 2px 12px; margin-top: 32px; margin-bottom: 14px; text-transform: uppercase; letter-spacing: 0.02em;\"\u003eWhere This Part Is Used\u003c\/h2\u003e\n\u003cul style=\"font-size: 15px; line-height: 1.65; margin-bottom: 16px; padding-left: 20px;\"\u003e\n\u003cli\u003eLow-temperature refrigeration systems\u003c\/li\u003e\n\u003cli\u003eCommercial freezers\u003c\/li\u003e\n\u003cli\u003eRefrigerated display units\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.65; margin-bottom: 16px;\"\u003eModel coverage can change across production runs — confirm against your unit's data plate before ordering.\u003c\/p\u003e\n\u003ch2 style=\"color: #14212e; font-size: 20px; border-left: 5px solid #d97706; padding: 2px 0 2px 12px; margin-top: 32px; margin-bottom: 14px; text-transform: uppercase; letter-spacing: 0.02em;\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 15px; margin-bottom: 18px; border-top: 2px solid #14212e;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #14212e; padding: 9px 10px; text-align: left; background-color: #eef1f4; border-bottom: 1px solid #d5dbe1; width: 38%;\"\u003eHorsepower (HP)\u003c\/th\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003e3\/8 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #14212e; padding: 9px 10px; text-align: left; background-color: #eef1f4; border-bottom: 1px solid #d5dbe1; width: 38%;\"\u003eVoltage\u003c\/th\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003e220–240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #14212e; padding: 9px 10px; text-align: left; background-color: #eef1f4; border-bottom: 1px solid #d5dbe1; width: 38%;\"\u003eRefrigerant Compatibility\u003c\/th\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003eR404A, R507\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #14212e; padding: 9px 10px; text-align: left; background-color: #eef1f4; border-bottom: 1px solid #d5dbe1; width: 38%;\"\u003eRated Capacity Range\u003c\/th\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003e58W (–45°C) to 1292W (–5°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"color: #14212e; font-size: 20px; border-left: 5px solid #d97706; padding: 2px 0 2px 12px; margin-top: 32px; margin-bottom: 14px; text-transform: uppercase; letter-spacing: 0.02em;\"\u003eCheck Before You Order\u003c\/h2\u003e\n\u003col style=\"font-size: 15px; line-height: 1.65; margin-bottom: 16px; padding-left: 20px;\"\u003e\n\u003cli\u003eVerify the existing compressor's model number and specifications against the SC12CL to confirm compatibility.\u003c\/li\u003e\n\u003cli\u003eConfirm the unit's electrical supply matches the 220–240V requirement of this compressor.\u003c\/li\u003e\n\u003cli\u003eEnsure your system uses R404A or R507 refrigerant. Mixing refrigerants can cause system failure.\u003c\/li\u003e\n\u003cli\u003eExamine mounting points and connection types to ensure the SC12CL will fit physically and functionally within your existing setup.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 style=\"color: #14212e; font-size: 20px; border-left: 5px solid #d97706; padding: 2px 0 2px 12px; margin-top: 32px; margin-bottom: 14px; text-transform: uppercase; letter-spacing: 0.02em;\"\u003eFitting Notes\u003c\/h2\u003e\n\u003cul style=\"font-size: 15px; line-height: 1.65; margin-bottom: 16px; padding-left: 20px;\"\u003e\n\u003cli\u003eInstallation and service of refrigerant circuits must be performed by a technician holding a current ARCtick licence.\u003c\/li\u003e\n\u003cli\u003eEnsure the system is fully discharged and recovered before removing the old compressor.\u003c\/li\u003e\n\u003cli\u003eAlways replace the filter drier when replacing a compressor.\u003c\/li\u003e\n\u003cli\u003eAdhere to manufacturer specifications for torque settings on all connection points to prevent leaks.\u003c\/li\u003e\n\u003cli\u003eEvacuate the system to a deep vacuum and recharge with the correct type and amount of refrigerant and oil.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #14212e; font-size: 20px; border-left: 5px solid #d97706; padding: 2px 0 2px 12px; margin-top: 32px; margin-bottom: 14px; text-transform: uppercase; letter-spacing: 0.02em;\"\u003eOrdering \u0026amp; Availability\u003c\/h2\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.65; margin-bottom: 16px;\"\u003eThis is a genuine Secop compressor. Sold individually unless a pack quantity is shown above. Current stock levels and estimated lead times are provided during checkout. Order from HVAC Trade Supply.\u003c\/p\u003e\n\u003ch2 style=\"color: #14212e; font-size: 20px; border-left: 5px solid #d97706; padding: 2px 0 2px 12px; margin-top: 32px; margin-bottom: 14px; text-transform: uppercase; letter-spacing: 0.02em;\"\u003eCommonly Ordered With\u003c\/h2\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.65; margin-bottom: 16px;\"\u003eTechnicians commonly order a suitable filter drier, expansion valve, and compressor oil when replacing a compressor.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Automated FAQ Schema --\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Which units or series does the Secop SC12CL fit, and how do I confirm against mine?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The Secop SC12CL compressor is designed for low-temperature refrigeration applications, including commercial freezers and display units using R404A or R507 refrigerant. Confirm fitment by checking your existing compressor's model number, refrigerant type, and voltage (220-240V) against the SC12CL specifications on your unit's data plate.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Is the Secop SC12CL a genuine\/OEM part or an aftermarket equivalent?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The SC12CL is a genuine Secop compressor, supplied directly by the manufacturer. It carries the manufacturer's code 104L2623, indicating it is an authentic Secop component.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Does fitting this part require a licensed tradesperson?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes, all work involving refrigerant circuits and recovery, including compressor replacement, must be carried out by a technician holding a current ARCtick licence in Australia. Electrical connections must be handled by a licensed electrician where applicable.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e","brand":"Secop","offers":[{"title":"Default Title","offer_id":50320969793773,"sku":"SC12CL","price":228.82,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/2737\/6621\/files\/153_LOW_20BACK_20PRESSURE_20COMPRESSORS.jpg?v=1784784266","url":"https:\/\/www.hvactradesupply.com.au\/products\/secop-sc12cl-compressor-r404a-r507-3-8hp-sc12cl","provider":"HVAC Trade Supply","version":"1.0","type":"link"}