{"product_id":"secop-compressor-r290-lbp-nle12-6cnl","title":"Secop Compressor NLE12.6CNL R290 LBP 220-240V","description":"\u003cdiv style=\"text-align: left; color: #26313d;\"\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.65; margin-bottom: 16px;\"\u003eThis is a Secop NLE12.6CNL fixed-speed compressor designed for Low Back Pressure (LBP) applications. It operates on 220-240V\/50Hz power and uses R290 refrigerant.\u003c\/p\u003e\n\u003ch2 style=\"color: #14212e; font-size: 20px; border-left: 5px solid #d97706; padding: 2px 0 2px 12px; margin-top: 32px; margin-bottom: 14px; text-transform: uppercase; letter-spacing: 0.02em;\"\u003ePart Identification\u003c\/h2\u003e\n\u003cul style=\"font-size: 15px; line-height: 1.65; margin-bottom: 16px; padding-left: 20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e NLE12.6CNL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Secop\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory:\u003c\/strong\u003e Compressor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Codes:\u003c\/strong\u003e 105H6378, 105H6376\u003c\/li\u003e\n\u003cli\u003eNo supersession data is listed for this part number.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #14212e; font-size: 20px; border-left: 5px solid #d97706; padding: 2px 0 2px 12px; margin-top: 32px; margin-bottom: 14px; text-transform: uppercase; letter-spacing: 0.02em;\"\u003eWhere This Part Is Used\u003c\/h2\u003e\n\u003cul style=\"font-size: 15px; line-height: 1.65; margin-bottom: 16px; padding-left: 20px;\"\u003e\n\u003cli\u003eLow Back Pressure (LBP) refrigeration systems.\u003c\/li\u003e\n\u003cli\u003eStationary medical cooling solutions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.65; margin-bottom: 16px;\"\u003eModel coverage can change across production runs — confirm against your unit's data plate before ordering.\u003c\/p\u003e\n\u003ch2 style=\"color: #14212e; font-size: 20px; border-left: 5px solid #d97706; padding: 2px 0 2px 12px; margin-top: 32px; margin-bottom: 14px; text-transform: uppercase; letter-spacing: 0.02em;\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 15px; margin-bottom: 18px; border-top: 2px solid #14212e;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #14212e; padding: 9px 10px; text-align: left; background-color: #eef1f4; border-bottom: 1px solid #d5dbe1; width: 38%;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"color: #14212e; padding: 9px 10px; text-align: left; background-color: #eef1f4; border-bottom: 1px solid #d5dbe1; width: 38%;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003e220-240V\/50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003eRefrigerant\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003eR290\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003eApplication\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003eLBP (Low Back Pressure)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003eMotor Type\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003eCSIR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003eDisplacement\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003e12.55 cm³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003eOil Charge\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003e300 cm³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003eOil Type\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003ePOE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003eHeight\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003e203 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003e11.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003eDischarge Connector Diameter\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003e6.2 mm (Copper)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003eProcess Connector Diameter\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003e6.2 mm (Copper)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003eSuction Connector Diameter\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003e8.2 mm (Copper)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003eMotor Speed\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003e2900 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003eLBP Cooling Capacity\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003e611 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003eLBP COP\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003e1.63 W\/W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"color: #14212e; font-size: 20px; border-left: 5px solid #d97706; padding: 2px 0 2px 12px; margin-top: 32px; margin-bottom: 14px; text-transform: uppercase; letter-spacing: 0.02em;\"\u003eCheck Before You Order\u003c\/h2\u003e\n\u003col style=\"font-size: 15px; line-height: 1.65; margin-bottom: 16px; padding-left: 20px;\"\u003e\n\u003cli\u003eVerify the compressor model number \u003cstrong\u003eNLE12.6CNL\u003c\/strong\u003e matches the unit's data plate exactly.\u003c\/li\u003e\n\u003cli\u003eConfirm the system operates on \u003cstrong\u003eR290\u003c\/strong\u003e refrigerant.\u003c\/li\u003e\n\u003cli\u003eEnsure the power supply required is \u003cstrong\u003e220-240V\/50Hz\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eCheck suction (8.2 mm), discharge (6.2 mm), and process (6.2 mm) line diameters against your existing pipework.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 style=\"color: #14212e; font-size: 20px; border-left: 5px solid #d97706; padding: 2px 0 2px 12px; margin-top: 32px; margin-bottom: 14px; text-transform: uppercase; letter-spacing: 0.02em;\"\u003eFitting Notes\u003c\/h2\u003e\n\u003cul style=\"font-size: 15px; line-height: 1.65; margin-bottom: 16px; padding-left: 20px;\"\u003e\n\u003cli\u003eInstallation requires a current ARCtick licence for refrigerant handling.\u003c\/li\u003e\n\u003cli\u003eAlways isolate power and follow lockout\/tagout procedures before commencing work.\u003c\/li\u003e\n\u003cli\u003eEnsure the system is properly evacuated and charged to manufacturer specifications after replacement.\u003c\/li\u003e\n\u003cli\u003eReplace the system filter drier when replacing the compressor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #14212e; font-size: 20px; border-left: 5px solid #d97706; padding: 2px 0 2px 12px; margin-top: 32px; margin-bottom: 14px; text-transform: uppercase; letter-spacing: 0.02em;\"\u003eOrdering \u0026amp; Availability\u003c\/h2\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.65; margin-bottom: 16px;\"\u003eThis is a genuine Secop NLE12.6CNL compressor. Sold individually. Current stock levels and estimated lead times are provided at checkout. Order from HVAC Trade Supply.\u003c\/p\u003e\n\u003ch2 style=\"color: #14212e; font-size: 20px; border-left: 5px solid #d97706; padding: 2px 0 2px 12px; margin-top: 32px; margin-bottom: 14px; text-transform: uppercase; letter-spacing: 0.02em;\"\u003eCommonly Ordered With\u003c\/h2\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.65; margin-bottom: 16px;\"\u003eCommonly ordered with a new filter drier, a pressure switch, and appropriate R290 refrigerant.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Automated FAQ Schema --\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Does fitting this part require a licensed tradesperson?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes, installing the Secop NLE12.6CNL compressor requires an ARCtick-licensed technician due to refrigerant handling requirements.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Which units or series does it fit, and how do I confirm against mine?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The NLE12.6CNL is designed for LBP (Low Back Pressure) refrigeration systems and stationary medical cooling. Confirm fitment by cross-referencing the full model number and specifications on your unit's data plate before ordering.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What do I measure or check to be certain before I order?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Before ordering the NLE12.6CNL, verify the model number, confirm R290 refrigerant use, check the 220-240V\/50Hz power supply, and measure the suction (8.2mm), discharge (6.2mm), and process (6.2mm) connector diameters.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e","brand":"Secop","offers":[{"title":"Default Title","offer_id":50320970285293,"sku":"NLE12.6CNL","price":290.4,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/2737\/6621\/files\/csm_n-series-image-center_7d2387f37f.png?v=1784784275","url":"https:\/\/www.hvactradesupply.com.au\/products\/secop-compressor-r290-lbp-nle12-6cnl","provider":"HVAC Trade Supply","version":"1.0","type":"link"}