{"product_id":"secop-compressor-r134a-220-240v-50hz-nl11mf","title":"Secop Compressor R134a 220-240V\/50Hz NL11MF","description":"\u003cdiv style=\"text-align: left; color: #26313d;\"\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.65; margin-bottom: 16px;\"\u003eThe Secop NL11MF is a fixed-speed compressor designed for R134a refrigerant applications. It operates on 220-240V\/50Hz power and is suitable for Medium (MBP) and High Back Pressure (HBP) systems.\u003c\/p\u003e\n\u003ch2 style=\"color: #14212e; font-size: 20px; border-left: 5px solid #d97706; padding: 2px 0 2px 12px; margin-top: 32px; margin-bottom: 14px; text-transform: uppercase; letter-spacing: 0.02em;\"\u003ePart Identification\u003c\/h2\u003e\n\u003cul style=\"font-size: 15px; line-height: 1.65; margin-bottom: 16px; padding-left: 20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e NL11MF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number (MPN):\u003c\/strong\u003e NL11MF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Secop\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Category:\u003c\/strong\u003e Hermetic Compressor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVariant Code Numbers:\u003c\/strong\u003e 105G6156, 105G6151, 105G6154, 105G6159\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.65; margin-bottom: 16px;\"\u003eNo supersession data is listed for this part number.\u003c\/p\u003e\n\u003ch2 style=\"color: #14212e; font-size: 20px; border-left: 5px solid #d97706; padding: 2px 0 2px 12px; margin-top: 32px; margin-bottom: 14px; text-transform: uppercase; letter-spacing: 0.02em;\"\u003eWhere This Part Is Used\u003c\/h2\u003e\n\u003cul style=\"font-size: 15px; line-height: 1.65; margin-bottom: 16px; padding-left: 20px;\"\u003e\n\u003cli\u003eStationary cooling solutions\u003c\/li\u003e\n\u003cli\u003eMedical cooling solutions\u003c\/li\u003e\n\u003cli\u003eMedium Back Pressure (MBP) applications\u003c\/li\u003e\n\u003cli\u003eHigh Back Pressure (HBP) applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.65; margin-bottom: 16px;\"\u003eModel coverage can change across production runs — confirm against your unit's data plate before ordering.\u003c\/p\u003e\n\u003ch2 style=\"color: #14212e; font-size: 20px; border-left: 5px solid #d97706; padding: 2px 0 2px 12px; margin-top: 32px; margin-bottom: 14px; text-transform: uppercase; letter-spacing: 0.02em;\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 15px; margin-bottom: 18px; border-top: 2px solid #14212e;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #14212e; padding: 9px 10px; text-align: left; background-color: #eef1f4; border-bottom: 1px solid #d5dbe1; width: 38%;\"\u003ePower Supply\u003c\/th\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003e220-240V\/50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #14212e; padding: 9px 10px; text-align: left; background-color: #eef1f4; border-bottom: 1px solid #d5dbe1; width: 38%;\"\u003eRefrigerant Compatibility\u003c\/th\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003eR134a\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #14212e; padding: 9px 10px; text-align: left; background-color: #eef1f4; border-bottom: 1px solid #d5dbe1; width: 38%;\"\u003eApplication Range\u003c\/th\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003eMBP, HBP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #14212e; padding: 9px 10px; text-align: left; background-color: #eef1f4; border-bottom: 1px solid #d5dbe1; width: 38%;\"\u003eMotor Type\u003c\/th\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003eRSIR, CSIR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #14212e; padding: 9px 10px; text-align: left; background-color: #eef1f4; border-bottom: 1px solid #d5dbe1; width: 38%;\"\u003eDisplacement\u003c\/th\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003e11.15 cm³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #14212e; padding: 9px 10px; text-align: left; background-color: #eef1f4; border-bottom: 1px solid #d5dbe1; width: 38%;\"\u003eOil Charge\u003c\/th\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003e300 cm³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #14212e; padding: 9px 10px; text-align: left; background-color: #eef1f4; border-bottom: 1px solid #d5dbe1; width: 38%;\"\u003eOil Type\u003c\/th\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003ePOE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #14212e; padding: 9px 10px; text-align: left; background-color: #eef1f4; border-bottom: 1px solid #d5dbe1; width: 38%;\"\u003eHeight\u003c\/th\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003e203 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #14212e; padding: 9px 10px; text-align: left; background-color: #eef1f4; border-bottom: 1px solid #d5dbe1; width: 38%;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003e10.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #14212e; padding: 9px 10px; text-align: left; background-color: #eef1f4; border-bottom: 1px solid #d5dbe1; width: 38%;\"\u003eDischarge Connector Ø\u003c\/th\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003e6.2 mm \/ 6.5 mm (depending on variant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #14212e; padding: 9px 10px; text-align: left; background-color: #eef1f4; border-bottom: 1px solid #d5dbe1; width: 38%;\"\u003eDischarge Material\u003c\/th\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003eCopper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #14212e; padding: 9px 10px; text-align: left; background-color: #eef1f4; border-bottom: 1px solid #d5dbe1; width: 38%;\"\u003eProcess Connector Ø\u003c\/th\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003e6.2 mm \/ 6.5 mm (depending on variant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #14212e; padding: 9px 10px; text-align: left; background-color: #eef1f4; border-bottom: 1px solid #d5dbe1; width: 38%;\"\u003eProcess Material\u003c\/th\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003eCopper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #14212e; padding: 9px 10px; text-align: left; background-color: #eef1f4; border-bottom: 1px solid #d5dbe1; width: 38%;\"\u003eSuction Connector Ø\u003c\/th\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003e8.2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #14212e; padding: 9px 10px; text-align: left; background-color: #eef1f4; border-bottom: 1px solid #d5dbe1; width: 38%;\"\u003eSuction Material\u003c\/th\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003eCopper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #14212e; padding: 9px 10px; text-align: left; background-color: #eef1f4; border-bottom: 1px solid #d5dbe1; width: 38%;\"\u003eMotor Speed\u003c\/th\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003e2900 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #14212e; padding: 9px 10px; text-align: left; background-color: #eef1f4; border-bottom: 1px solid #d5dbe1; width: 38%;\"\u003eMBP Cooling Capacity\u003c\/th\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003e623 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #14212e; padding: 9px 10px; text-align: left; background-color: #eef1f4; border-bottom: 1px solid #d5dbe1; width: 38%;\"\u003eHBP Cooling Capacity\u003c\/th\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003e1115 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"color: #14212e; font-size: 20px; border-left: 5px solid #d97706; padding: 2px 0 2px 12px; margin-top: 32px; margin-bottom: 14px; text-transform: uppercase; letter-spacing: 0.02em;\"\u003eCheck Before You Order\u003c\/h2\u003e\n\u003col style=\"font-size: 15px; line-height: 1.65; margin-bottom: 16px; padding-left: 20px;\"\u003e\n\u003cli\u003eVerify the existing compressor's model number and operating voltage against the NL11MF specifications.\u003c\/li\u003e\n\u003cli\u003eConfirm the refrigerant type required for your system is R134a.\u003c\/li\u003e\n\u003cli\u003eMeasure the existing suction, discharge, and process connector diameters to ensure fitment.\u003c\/li\u003e\n\u003cli\u003eCheck if your application requires a Medium Back Pressure (MBP) or High Back Pressure (HBP) compressor.\u003c\/li\u003e\n\u003cli\u003eEnsure the physical dimensions, particularly height and mounting, align with the available space in your unit.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 style=\"color: #14212e; font-size: 20px; border-left: 5px solid #d97706; padding: 2px 0 2px 12px; margin-top: 32px; margin-bottom: 14px; text-transform: uppercase; letter-spacing: 0.02em;\"\u003eFitting Notes\u003c\/h2\u003e\n\u003cul style=\"font-size: 15px; line-height: 1.65; margin-bottom: 16px; padding-left: 20px;\"\u003e\n\u003cli\u003eThe refrigeration system must be fully recovered and isolated before compressor replacement.\u003c\/li\u003e\n\u003cli\u003eAlways replace the filter drier when installing a new compressor.\u003c\/li\u003e\n\u003cli\u003eEnsure the correct type and volume of POE oil are used during installation.\u003c\/li\u003e\n\u003cli\u003eInstallation and commissioning of this refrigeration component must be carried out by an ARCtick licensed technician.\u003c\/li\u003e\n\u003cli\u003eAll electrical connections must be performed by a licensed electrician.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #14212e; font-size: 20px; border-left: 5px solid #d97706; padding: 2px 0 2px 12px; margin-top: 32px; margin-bottom: 14px; text-transform: uppercase; letter-spacing: 0.02em;\"\u003eOrdering \u0026amp; Availability\u003c\/h2\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.65; margin-bottom: 16px;\"\u003eThe Secop NL11MF compressor is a genuine OEM part. Sold individually. Stock levels and current lead times are displayed at checkout. Order from HVAC Trade Supply.\u003c\/p\u003e\n\u003ch2 style=\"color: #14212e; font-size: 20px; border-left: 5px solid #d97706; padding: 2px 0 2px 12px; margin-top: 32px; margin-bottom: 14px; text-transform: uppercase; letter-spacing: 0.02em;\"\u003eCommonly Ordered With\u003c\/h2\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.65; margin-bottom: 16px;\"\u003eCommonly ordered with suitable filter driers, compressor starting relays, and system line taps.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Automated FAQ Schema --\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Which units or series does it fit, and how do I confirm against mine?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The Secop NL11MF compressor fits medical and stationary cooling applications requiring R134a with MBP or HBP conditions. Confirm fitment by matching the existing compressor's model number, refrigerant type, and electrical specifications on your unit's data plate.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Does fitting this part require a licensed tradesperson (ARCtick or electrical)?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes, all work involving refrigerant circuits, including compressor replacement, must be performed by an ARCtick licensed technician. Any associated electrical work requires a licensed electrician.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What do I measure or check to be certain before I order?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Before ordering the NL11MF, confirm the operating voltage (220-240V\/50Hz), required refrigerant (R134a), and application type (MBP\/HBP) from your unit's specifications. Additionally, verify the physical dimensions and connector diameters against your existing compressor.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e","brand":"Secop","offers":[{"title":"Default Title","offer_id":50320972185837,"sku":"NL11MF","price":224.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/2737\/6621\/files\/csm_n-series-image-center_7d2387f37f_4fe251c0-90e9-4df1-bdff-3095ea1f6246.png?v=1784784296","url":"https:\/\/www.hvactradesupply.com.au\/products\/secop-compressor-r134a-220-240v-50hz-nl11mf","provider":"HVAC Trade Supply","version":"1.0","type":"link"}