{"product_id":"secop-compressor-nl8-4mf","title":"Secop Compressor NL8.4MF R134a\/R513A 220-240V","description":"\u003cdiv style=\"text-align: left; color: #26313d;\"\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.65; margin-bottom: 16px;\"\u003eThe Secop NL8.4MF compressor is a fixed-speed hermetic unit designed for R134a and R513A refrigerant systems. It operates on a 220-240V\/50Hz power supply and is suitable for LBP and MBP applications.\u003c\/p\u003e\n\u003ch2 style=\"color: #14212e; font-size: 20px; border-left: 5px solid #d97706; padding: 2px 0 2px 12px; margin-top: 32px; margin-bottom: 14px; text-transform: uppercase; letter-spacing: 0.02em;\"\u003ePart Identification\u003c\/h2\u003e\n\u003cul style=\"font-size: 15px; line-height: 1.65; margin-bottom: 16px; padding-left: 20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e NL8.4MF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Code:\u003c\/strong\u003e 105G7802\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Secop\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Category:\u003c\/strong\u003e Hermetic Compressor\u003c\/li\u003e\n\u003cli\u003eNo supersession data is listed for this part number.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #14212e; font-size: 20px; border-left: 5px solid #d97706; padding: 2px 0 2px 12px; margin-top: 32px; margin-bottom: 14px; text-transform: uppercase; letter-spacing: 0.02em;\"\u003eWhere This Part Is Used\u003c\/h2\u003e\n\u003cul style=\"font-size: 15px; line-height: 1.65; margin-bottom: 16px; padding-left: 20px;\"\u003e\n\u003cli\u003eStationary \/ Medical Cooling Solutions\u003c\/li\u003e\n\u003cli\u003eLow Back Pressure (LBP) applications\u003c\/li\u003e\n\u003cli\u003eMedium Back Pressure (MBP) applications\u003c\/li\u003e\n\u003cli\u003eRefrigerant systems using R134a or R513A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.65; margin-bottom: 16px;\"\u003eModel coverage can change across production runs — confirm against your unit's data plate before ordering.\u003c\/p\u003e\n\u003ch2 style=\"color: #14212e; font-size: 20px; border-left: 5px solid #d97706; padding: 2px 0 2px 12px; margin-top: 32px; margin-bottom: 14px; text-transform: uppercase; letter-spacing: 0.02em;\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 15px; margin-bottom: 18px; border-top: 2px solid #14212e;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #14212e; padding: 9px 10px; text-align: left; background-color: #eef1f4; border-bottom: 1px solid #d5dbe1; width: 38%;\"\u003ePower Supply\u003c\/th\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003e220-240V\/50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #14212e; padding: 9px 10px; text-align: left; background-color: #eef1f4; border-bottom: 1px solid #d5dbe1; width: 38%;\"\u003eRefrigerants\u003c\/th\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003eR134a, R513A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #14212e; padding: 9px 10px; text-align: left; background-color: #eef1f4; border-bottom: 1px solid #d5dbe1; width: 38%;\"\u003eApplications\u003c\/th\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003eLBP, MBP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #14212e; padding: 9px 10px; text-align: left; background-color: #eef1f4; border-bottom: 1px solid #d5dbe1; width: 38%;\"\u003eMotor Type\u003c\/th\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003eRSIR, CSIR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #14212e; padding: 9px 10px; text-align: left; background-color: #eef1f4; border-bottom: 1px solid #d5dbe1; width: 38%;\"\u003eDisplacement\u003c\/th\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003e8.35 cm³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #14212e; padding: 9px 10px; text-align: left; background-color: #eef1f4; border-bottom: 1px solid #d5dbe1; width: 38%;\"\u003eHeight\u003c\/th\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003e197 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #14212e; padding: 9px 10px; text-align: left; background-color: #eef1f4; border-bottom: 1px solid #d5dbe1; width: 38%;\"\u003eWeight\u003c\/th\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003e10.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #14212e; padding: 9px 10px; text-align: left; background-color: #eef1f4; border-bottom: 1px solid #d5dbe1; width: 38%;\"\u003eDischarge Connector Ø\u003c\/th\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003e6.2 mm (Copper)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #14212e; padding: 9px 10px; text-align: left; background-color: #eef1f4; border-bottom: 1px solid #d5dbe1; width: 38%;\"\u003eSuction Connector Ø\u003c\/th\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003e8.2 mm (Copper)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #14212e; padding: 9px 10px; text-align: left; background-color: #eef1f4; border-bottom: 1px solid #d5dbe1; width: 38%;\"\u003eProcess Connector Ø\u003c\/th\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003e6.2 mm (Copper)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #14212e; padding: 9px 10px; text-align: left; background-color: #eef1f4; border-bottom: 1px solid #d5dbe1; width: 38%;\"\u003eOil Charge\u003c\/th\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003e270 cm³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #14212e; padding: 9px 10px; text-align: left; background-color: #eef1f4; border-bottom: 1px solid #d5dbe1; width: 38%;\"\u003eOil Type\u003c\/th\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003ePOE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #14212e; padding: 9px 10px; text-align: left; background-color: #eef1f4; border-bottom: 1px solid #d5dbe1; width: 38%;\"\u003eMotor Speed\u003c\/th\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003e2900 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #14212e; padding: 9px 10px; text-align: left; background-color: #eef1f4; border-bottom: 1px solid #d5dbe1; width: 38%;\"\u003eLBP Cooling Capacity\u003c\/th\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003e219 W (748 Btu\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #14212e; padding: 9px 10px; text-align: left; background-color: #eef1f4; border-bottom: 1px solid #d5dbe1; width: 38%;\"\u003eMBP Cooling Capacity\u003c\/th\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003e454 W (1552 Btu\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"color: #14212e; font-size: 20px; border-left: 5px solid #d97706; padding: 2px 0 2px 12px; margin-top: 32px; margin-bottom: 14px; text-transform: uppercase; letter-spacing: 0.02em;\"\u003eCheck Before You Order\u003c\/h2\u003e\n\u003col style=\"font-size: 15px; line-height: 1.65; margin-bottom: 16px; padding-left: 20px;\"\u003e\n\u003cli\u003eVerify the unit's data plate specifies NL8.4MF or manufacturer code 105G7802.\u003c\/li\u003e\n\u003cli\u003eConfirm the existing compressor operates on 220-240V\/50Hz power supply.\u003c\/li\u003e\n\u003cli\u003eMeasure existing suction, discharge, and process line diameters for compatibility with 8.2mm and 6.2mm connections.\u003c\/li\u003e\n\u003cli\u003eEnsure the application is a Low Back Pressure (LBP) or Medium Back Pressure (MBP) system.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 style=\"color: #14212e; font-size: 20px; border-left: 5px solid #d97706; padding: 2px 0 2px 12px; margin-top: 32px; margin-bottom: 14px; text-transform: uppercase; letter-spacing: 0.02em;\"\u003eFitting Notes\u003c\/h2\u003e\n\u003cul style=\"font-size: 15px; line-height: 1.65; margin-bottom: 16px; padding-left: 20px;\"\u003e\n\u003cli\u003eElectrical isolation and lockout procedures are mandatory before commencing any installation work.\u003c\/li\u003e\n\u003cli\u003eRefrigerant recovery must be performed by an ARCtick licensed technician before disconnecting the existing compressor.\u003c\/li\u003e\n\u003cli\u003eApply appropriate torque to all refrigerant line connections to prevent leaks and ensure system integrity.\u003c\/li\u003e\n\u003cli\u003eA current ARCtick licence is required for handling refrigerants during installation and commissioning.\u003c\/li\u003e\n\u003cli\u003eAll electrical work related to compressor replacement must be carried out by a licensed electrician.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #14212e; font-size: 20px; border-left: 5px solid #d97706; padding: 2px 0 2px 12px; margin-top: 32px; margin-bottom: 14px; text-transform: uppercase; letter-spacing: 0.02em;\"\u003eOrdering \u0026amp; Availability\u003c\/h2\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.65; margin-bottom: 16px;\"\u003eThe Secop NL8.4MF compressor is a genuine OEM part. Sold individually unless a pack quantity is shown above. Stock levels and current lead times are displayed at checkout. Order from HVAC Trade Supply.\u003c\/p\u003e\n\u003ch2 style=\"color: #14212e; font-size: 20px; border-left: 5px solid #d97706; padding: 2px 0 2px 12px; margin-top: 32px; margin-bottom: 14px; text-transform: uppercase; letter-spacing: 0.02em;\"\u003eCommonly Ordered With\u003c\/h2\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.65; margin-bottom: 16px;\"\u003eCommonly ordered with compressor mounting kits, filter driers, and appropriate POE refrigeration oil.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Automated FAQ Schema --\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Does this part number supersede, or is it superseded by, another number?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"No supersession data is listed for the Secop NL8.4MF compressor. Always verify the part number against your unit's data plate or manufacturer documentation to confirm the correct replacement.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Is this a genuine\/OEM part or an aftermarket equivalent?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The NL8.4MF compressor is a genuine Secop OEM (Original Equipment Manufacturer) part. It is manufactured to original equipment specifications for reliable replacement in compatible systems.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Does fitting this part require a licensed tradesperson (ARCtick or electrical)?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes, installation of the Secop NL8.4MF compressor involves both refrigerant handling and electrical connections. A current ARCtick licence is required for refrigerant work, and a licensed electrician must carry out all electrical connections.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e","brand":"Secop","offers":[{"title":"Default Title","offer_id":50320972087533,"sku":"NL8.4MF","price":206.94,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/2737\/6621\/files\/csm_n-series-image-center_7d2387f37f_f4e1ec63-deab-452f-bb43-86a9f8eac82d.png?v=1784784294","url":"https:\/\/www.hvactradesupply.com.au\/products\/secop-compressor-nl8-4mf","provider":"HVAC Trade Supply","version":"1.0","type":"link"}