{"product_id":"danfoss-kp5-pressure-switch-auto-reset-dankp5-060-117191","title":"Danfoss KP5 Pressure Switch, Auto Reset | DANKP5-060-117191","description":"\u003cdiv style=\"text-align: left; color: #26313d;\"\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.65; margin-bottom: 16px;\"\u003eThis is a genuine Danfoss KP5 automatic reset pressure switch for high-pressure control in refrigeration and HVACR systems. It features an 8-32 bar regulation range with a 1\/4\" male flare pressure connection.\u003c\/p\u003e\n\u003ch2 style=\"color: #14212e; font-size: 20px; border-left: 5px solid #d97706; padding: 2px 0 2px 12px; margin-top: 32px; margin-bottom: 14px; text-transform: uppercase; letter-spacing: 0.02em;\"\u003ePart Identification\u003c\/h2\u003e\n\u003cul style=\"font-size: 15px; line-height: 1.65; margin-bottom: 16px; padding-left: 20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Name:\u003c\/strong\u003e Pressure switch, KP5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number (MPN):\u003c\/strong\u003e 060-117191\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Danfoss\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e Switches and thermostats\u003c\/li\u003e\n\u003cli\u003eNo supersession data is listed for this part number.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #14212e; font-size: 20px; border-left: 5px solid #d97706; padding: 2px 0 2px 12px; margin-top: 32px; margin-bottom: 14px; text-transform: uppercase; letter-spacing: 0.02em;\"\u003eWhere This Part Is Used\u003c\/h2\u003e\n\u003cul style=\"font-size: 15px; line-height: 1.65; margin-bottom: 16px; padding-left: 20px;\"\u003e\n\u003cli\u003eHigh-pressure protection in commercial refrigeration plants.\u003c\/li\u003e\n\u003cli\u003ePressure regulation in air conditioning and heat pump systems.\u003c\/li\u003e\n\u003cli\u003eCompatible with a wide range of refrigerants including R134a, R22, R404A, R407C, R448A, R449A, R507A, R513A, R515B.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication Note:\u003c\/strong\u003e Not applicable for liquid line.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.65; margin-bottom: 16px;\"\u003eModel coverage can change across production runs — confirm against your unit's data plate before ordering.\u003c\/p\u003e\n\u003ch2 style=\"color: #14212e; font-size: 20px; border-left: 5px solid #d97706; padding: 2px 0 2px 12px; margin-top: 32px; margin-bottom: 14px; text-transform: uppercase; letter-spacing: 0.02em;\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 15px; margin-bottom: 18px; border-top: 2px solid #14212e;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #14212e; padding: 9px 10px; text-align: left; background-color: #eef1f4; border-bottom: 1px solid #d5dbe1; width: 38%;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"color: #14212e; padding: 9px 10px; text-align: left; background-color: #eef1f4; border-bottom: 1px solid #d5dbe1; width: 38%;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003eRegulation Range [bar] Pe\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003e8 - 32 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003eDifferential [bar]\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003e1.8 - 6 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003eReset Function\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003eAuto\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003eContact Function\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003eSPDT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003ePressure Connection Type\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003eFlare, Male\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003ePressure Connection Size\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003e1\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003eMax. Working Pressure [bar]\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003e35 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003eEnclosure Rating IP\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003eIP44\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003eAmbient Temperature Range\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003e-40 to 65 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003eContact Rating (AC15)\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003e10 A, 400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003eGross Weight\u003c\/td\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003e0.338 Kilogram\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"color: #14212e; font-size: 20px; border-left: 5px solid #d97706; padding: 2px 0 2px 12px; margin-top: 32px; margin-bottom: 14px; text-transform: uppercase; letter-spacing: 0.02em;\"\u003eCheck Before You Order\u003c\/h2\u003e\n\u003col style=\"font-size: 15px; line-height: 1.65; margin-bottom: 16px; padding-left: 20px;\"\u003e\n\u003cli\u003eVerify the existing pressure switch is a Danfoss KP5 series with an automatic reset function.\u003c\/li\u003e\n\u003cli\u003eConfirm the pressure connection type and size matches your system's requirements, specifically a 1\/4\" male flare.\u003c\/li\u003e\n\u003cli\u003eCheck the required regulation pressure range and differential against your application's specifications.\u003c\/li\u003e\n\u003cli\u003eInspect the electrical connection and contact function (SPDT) to ensure compatibility with your control circuit.\u003c\/li\u003e\n\u003cli\u003eConfirm the operating ambient temperature range is suitable for your installation environment.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 style=\"color: #14212e; font-size: 20px; border-left: 5px solid #d97706; padding: 2px 0 2px 12px; margin-top: 32px; margin-bottom: 14px; text-transform: uppercase; letter-spacing: 0.02em;\"\u003eFitting Notes\u003c\/h2\u003e\n\u003cul style=\"font-size: 15px; line-height: 1.65; margin-bottom: 16px; padding-left: 20px;\"\u003e\n\u003cli\u003eAlways isolate electrical power and perform lockout\/tagout procedures before commencing work.\u003c\/li\u003e\n\u003cli\u003eEnsure the system pressure is safely discharged or isolated before removing the existing switch.\u003c\/li\u003e\n\u003cli\u003eRefrigerant circuit work must be carried out by a technician holding a current ARCtick licence.\u003c\/li\u003e\n\u003cli\u003eElectrical connections must be made by a licensed electrician in accordance with local regulations.\u003c\/li\u003e\n\u003cli\u003eApply appropriate torque when tightening flare connections to prevent leaks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #14212e; font-size: 20px; border-left: 5px solid #d97706; padding: 2px 0 2px 12px; margin-top: 32px; margin-bottom: 14px; text-transform: uppercase; letter-spacing: 0.02em;\"\u003eOrdering \u0026amp; Availability\u003c\/h2\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.65; margin-bottom: 16px;\"\u003eThis is a genuine Danfoss replacement part. It is sold individually, though manufactured and supplied in multi-packs of 36 by Danfoss. Current stock levels and estimated lead times are provided at checkout. Order from HVAC Trade Supply.\u003c\/p\u003e\n\u003ch2 style=\"color: #14212e; font-size: 20px; border-left: 5px solid #d97706; padding: 2px 0 2px 12px; margin-top: 32px; margin-bottom: 14px; text-transform: uppercase; letter-spacing: 0.02em;\"\u003eCommonly Ordered With\u003c\/h2\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.65; margin-bottom: 16px;\"\u003eTechnicians often order this pressure switch with new refrigerant, filter driers, or contactors.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Automated FAQ Schema --\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Which units or series does the Danfoss KP5 pressure switch fit, and how do I confirm against mine?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"The Danfoss KP5 (060-117191) is a universal high-pressure control used across various refrigeration and HVACR systems. Confirm fitment by matching the part number from your existing component or your unit's data plate, and ensure the 1\/4\\\" male flare connection and 8-32 bar regulation range are suitable for your application.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What do I measure or check to be certain before I order the DANKP5-060-117191?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Before ordering the DANKP5-060-117191, check your current switch for the Danfoss KP5 model and the 060-117191 MPN. Verify the pressure connection is a 1\/4\\\" male flare, and confirm the system requires an automatic reset function with an 8-32 bar regulation range.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Does fitting this Danfoss pressure switch require a licensed tradesperson?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes, installing the Danfoss KP5 pressure switch involves both electrical connections and working with pressurised refrigerant circuits. All electrical work must be performed by a licensed electrician, and any work on the refrigerant circuit requires a technician holding a current ARCtick licence.\"\n      }\n    }\n  ]\n}\n\u003c\/script\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":50321108402413,"sku":"DANKP5-060-117191","price":89.99,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/2737\/6621\/files\/ID337639774733-0201_preview.jpg?v=1784788025","url":"https:\/\/www.hvactradesupply.com.au\/products\/danfoss-kp5-pressure-switch-auto-reset-dankp5-060-117191","provider":"HVAC Trade Supply","version":"1.0","type":"link"}