{"product_id":"danfoss-kp1-low-pressure-switch-auto-reset-dankp1-060-1101","title":"Danfoss KP1 Low Pressure Switch Auto Reset | DANKP1-060-1101","description":"\u003cdiv style=\"text-align: left; color: #26313d;\"\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.65; margin-bottom: 16px;\"\u003eThis is a Danfoss KP1 low pressure switch with automatic reset functionality. It features a regulation range of -0.2 to 7.5 bar and a 1\/4\" flare male connection.\u003c\/p\u003e\n\u003ch2 style=\"color: #14212e; font-size: 20px; border-left: 5px solid #d97706; padding: 2px 0 2px 12px; margin-top: 32px; margin-bottom: 14px; text-transform: uppercase; letter-spacing: 0.02em;\"\u003ePart Identification\u003c\/h2\u003e\n\u003cul style=\"font-size: 15px; line-height: 1.65; margin-bottom: 16px; padding-left: 20px;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e DANKP1-060-1101\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number (MPN):\u003c\/strong\u003e 060-110191\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Danfoss\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Group:\u003c\/strong\u003e Switches and Thermostats\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e KP1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReset Function:\u003c\/strong\u003e Auto\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.65; margin-bottom: 16px;\"\u003eNo supersession data is listed for this part number.\u003c\/p\u003e\n\u003ch2 style=\"color: #14212e; font-size: 20px; border-left: 5px solid #d97706; padding: 2px 0 2px 12px; margin-top: 32px; margin-bottom: 14px; text-transform: uppercase; letter-spacing: 0.02em;\"\u003eWhere This Part Is Used\u003c\/h2\u003e\n\u003cul style=\"font-size: 15px; line-height: 1.65; margin-bottom: 16px; padding-left: 20px;\"\u003e\n\u003cli\u003eUsed in refrigeration and air conditioning systems.\u003c\/li\u003e\n\u003cli\u003eDesigned for oil-free applications.\u003c\/li\u003e\n\u003cli\u003eCompatible with refrigerants including R134a, R22, R404A, R407C, R448A, R449A, R507A, R513A, R515B.\u003c\/li\u003e\n\u003cli\u003eNot applicable for liquid line installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.65; margin-bottom: 16px;\"\u003eModel coverage can change across production runs — confirm against your unit's data plate before ordering.\u003c\/p\u003e\n\u003ch2 style=\"color: #14212e; font-size: 20px; border-left: 5px solid #d97706; padding: 2px 0 2px 12px; margin-top: 32px; margin-bottom: 14px; text-transform: uppercase; letter-spacing: 0.02em;\"\u003eSpecifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 15px; margin-bottom: 18px; border-top: 2px solid #14212e;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #14212e; padding: 9px 10px; text-align: left; background-color: #eef1f4; border-bottom: 1px solid #d5dbe1; width: 38%;\"\u003eRegulation Range [bar] Pe\u003c\/th\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003e-0.2 - 7.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #14212e; padding: 9px 10px; text-align: left; background-color: #eef1f4; border-bottom: 1px solid #d5dbe1; width: 38%;\"\u003eDifferential [bar]\u003c\/th\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003e0.7 - 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #14212e; padding: 9px 10px; text-align: left; background-color: #eef1f4; border-bottom: 1px solid #d5dbe1; width: 38%;\"\u003eMax. Working Pressure [bar]\u003c\/th\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003e17\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #14212e; padding: 9px 10px; text-align: left; background-color: #eef1f4; border-bottom: 1px solid #d5dbe1; width: 38%;\"\u003eMax. Test Pressure [bar] Pe\u003c\/th\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #14212e; padding: 9px 10px; text-align: left; background-color: #eef1f4; border-bottom: 1px solid #d5dbe1; width: 38%;\"\u003eContact Function\u003c\/th\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003eSPDT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #14212e; padding: 9px 10px; text-align: left; background-color: #eef1f4; border-bottom: 1px solid #d5dbe1; width: 38%;\"\u003eContact Rating (AC15)\u003c\/th\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003e10 A, 400 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #14212e; padding: 9px 10px; text-align: left; background-color: #eef1f4; border-bottom: 1px solid #d5dbe1; width: 38%;\"\u003ePressure Connection Type\u003c\/th\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003eFlare\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #14212e; padding: 9px 10px; text-align: left; background-color: #eef1f4; border-bottom: 1px solid #d5dbe1; width: 38%;\"\u003ePressure Connection Size\u003c\/th\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003e1\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #14212e; padding: 9px 10px; text-align: left; background-color: #eef1f4; border-bottom: 1px solid #d5dbe1; width: 38%;\"\u003ePressure Male\/Female\u003c\/th\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003eMale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #14212e; padding: 9px 10px; text-align: left; background-color: #eef1f4; border-bottom: 1px solid #d5dbe1; width: 38%;\"\u003eEnclosure Rating IP\u003c\/th\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003eIP44\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #14212e; padding: 9px 10px; text-align: left; background-color: #eef1f4; border-bottom: 1px solid #d5dbe1; width: 38%;\"\u003eAmbient Temperature Range [°C]\u003c\/th\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003e-25 to 65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"color: #14212e; padding: 9px 10px; text-align: left; background-color: #eef1f4; border-bottom: 1px solid #d5dbe1; width: 38%;\"\u003eGross Weight\u003c\/th\u003e\n\u003ctd style=\"padding: 9px 10px; border-bottom: 1px solid #e6eaee;\"\u003e0.336 Kilogram\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"color: #14212e; font-size: 20px; border-left: 5px solid #d97706; padding: 2px 0 2px 12px; margin-top: 32px; margin-bottom: 14px; text-transform: uppercase; letter-spacing: 0.02em;\"\u003eCheck Before You Order\u003c\/h2\u003e\n\u003col style=\"font-size: 15px; line-height: 1.65; margin-bottom: 16px; padding-left: 20px;\"\u003e\n\u003cli\u003eVerify the part number 060-110191 matches the existing switch on your unit.\u003c\/li\u003e\n\u003cli\u003eConfirm the regulation range and differential settings are appropriate for your system's operating parameters.\u003c\/li\u003e\n\u003cli\u003eCheck the pressure connection type and size (1\/4\" flare male) against your system's pipework.\u003c\/li\u003e\n\u003cli\u003eEnsure the auto-reset function is suitable; do not substitute for manual reset types without system redesign.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2 style=\"color: #14212e; font-size: 20px; border-left: 5px solid #d97706; padding: 2px 0 2px 12px; margin-top: 32px; margin-bottom: 14px; text-transform: uppercase; letter-spacing: 0.02em;\"\u003eFitting Notes\u003c\/h2\u003e\n\u003cul style=\"font-size: 15px; line-height: 1.65; margin-bottom: 16px; padding-left: 20px;\"\u003e\n\u003cli\u003eIsolate and lockout the electrical supply to the unit before commencing any work.\u003c\/li\u003e\n\u003cli\u003eEnsure the refrigeration circuit is depressurised and recovered by an ARCtick licensed technician before disconnecting pressure lines.\u003c\/li\u003e\n\u003cli\u003eFit the pressure switch ensuring the flare connection is correctly seated and torqued to prevent leaks.\u003c\/li\u003e\n\u003cli\u003eAll electrical connections must be carried out by a licensed electrician in accordance with local regulations.\u003c\/li\u003e\n\u003cli\u003eThis switch is not for liquid line use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #14212e; font-size: 20px; border-left: 5px solid #d97706; padding: 2px 0 2px 12px; margin-top: 32px; margin-bottom: 14px; text-transform: uppercase; letter-spacing: 0.02em;\"\u003eOrdering \u0026amp; Availability\u003c\/h2\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.65; margin-bottom: 16px;\"\u003eThis genuine Danfoss KP1 pressure switch is typically sold individually. Some supplier packs contain 36 pieces; confirm unit of sale when adding to cart. Stock levels and lead times are displayed at checkout. Order from HVAC Trade Supply.\u003c\/p\u003e\n\u003ch2 style=\"color: #14212e; font-size: 20px; border-left: 5px solid #d97706; padding: 2px 0 2px 12px; margin-top: 32px; margin-bottom: 14px; text-transform: uppercase; letter-spacing: 0.02em;\"\u003eCommonly Ordered With\u003c\/h2\u003e\n\u003cp style=\"font-size: 15px; line-height: 1.65; margin-bottom: 16px;\"\u003eCommonly ordered with flared union fittings, refrigerant, and pressure gauge sets.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- Automated FAQ Schema --\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":50321108467949,"sku":"DANKP1-060-1101","price":99.99,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0741\/2737\/6621\/files\/s-l1600_4e1c47c1-065e-4055-b19e-41eb2e63b30c.webp?v=1784788088","url":"https:\/\/www.hvactradesupply.com.au\/products\/danfoss-kp1-low-pressure-switch-auto-reset-dankp1-060-1101","provider":"HVAC Trade Supply","version":"1.0","type":"link"}